Pump head from system losses and boundaries
A pump must supply the difference in total energy between system boundaries plus dissipative losses. Separate static lift from friction: static requirements can remain when flow is zero, while velocity-dependent losses change with flow.
Worked numbers are illustrative. Use your own operating conditions and documented material/process data.
Required inputs
- Boundary elevations and pressures on a consistent gauge or absolute basis.
- Flow, pipe segments and fitting/equipment losses.
- Fluid density and pump efficiency at the intended duty; a user-supplied pump curve if seeking an operating point.
Governing equations
Hrequired = Δz + Δp/(ρg) + Δ(v²)/(2g) + Σhloss
Phydraulic = ρgQH
Pshaft = Phydraulic/ηpump
Variables and units
- H, z and losses: m; p: Pa; Q: m³/s; P: W.
- ηpump is a decimal between 0 and 1; motor electrical input requires a separate motor efficiency.
Assumptions
- Steady liquid-flow energy balance between stated boundaries.
- For two large open tanks, equal boundary pressure and negligible tank velocity remove the pressure and velocity terms.
Calculation workflow
- Define start and end boundaries before counting losses.
- Sum static, pressure, velocity and dissipative contributions without counting a component twice.
- Compare required head with a supplied pump curve only over its supported flow range.
Worked example
- Two open tanks differ by 10 m elevation; flow is 25 m³/h. Entered pipe/equipment losses sum to 4 m.
- Hrequired = 10 + 4 = 14 m. With ρ = 1000 kg/m³ and g = 9.81 m/s², Phydraulic = 0.953750 kW.
- At entered pump efficiency 0.75, Pshaft = 1.271667 kW.
Limitations
- NPSHA requires pressure, vapor pressure, elevations and suction losses on the correct absolute basis; NPSHr requires pump data.
- Parallel-network balancing, cavitation approval and water-hammer analysis are not provided by this energy balance.
Common mistakes
- Adding static lift to a pressure-head term that already includes it.
- Using gauge pressure as absolute pressure in NPSH work.
- Extrapolating a pump curve or treating hydraulic power as electrical input.
Practical interpretation
At a specified flow, this is the required duty, not proof that a pump will achieve it. The operating point is the intersection with a real supplied pump curve. An illustrative system curve cannot create a manufacturer pump curve or establish NPSHr.